ARMOURED DIRECT BURIAL CABLES

APPLICATION
Direct burial underground or ducts for high-speed voice, Data and Video communications and Long haul Telecommunications. Suitable for laying in areas subjected to rodent hazard.
MULTITUBE DESIGN
Tubes containing primary coated fibres stranded around a central strength member, filled with jelly, sheathed with P.E. An armour of corrugated steel tape between the inner and outer PE sheath provides the necessary strength required for Direct buried applications. New Minizip designs with tight buffered fibres upto 600 microns for simplex & duplex cables.
UNITUBE DESIGN
Loose tube containing fibres is jacketed with steel wire strength members embedded in the sheath OR Loose tube buffered with aramid yarn for strength sheathed with PE/LSZH, corrugated steel tape armoured overall PE/LSZH jacketed provides the necessary strength and protection.
Features
Unitube designs are for low fibre counts, having necessary strength & smaller diameters.
MECHANICAL PROPERTIES
High Tensile Strength, high compression resistance (4000 N) and stability over temperature range of -200 C to +700 C.
In dry core design stability over temperature range of -40 deg. C to + 70 deg. C..

UNITUBE DESIGN

Uni Tube Design
Uni Tube Design
Uni Tube Design
PHYSICAL PARAMETERS
PART NUMBER FIBRE COUNT DIAMETER(mm)(±1.0) WEIGHT(Kg./Km) TENSILE STRENGTH (Newton) BENDINGRADIUS(mm)
Temp. Perm.
B-4/62.5/UT(2W)-CCSTP-B11.0* UPTO 6 FIBRE 11.0 135±10 2800
75 110
B-8/SM/UT(2W)-CCSTP-B11.0* 8 TO 12 FIBRE 11.0 135±10 2800
75 110
B-14/SM/UT(2W)-CCSTP-B11.0* 14 TO 24 FIBRE 11.0 135±10 2800
75 110

UNITUBE DESIGN

Uni Tube Design
Uni Tube Design
Uni Tube Design
PHYSICAL PARAMETERS
PART NUMBER FIBRE COUNT DIAMETER(mm)(±1.0) WEIGHT(Kg./Km) TENSILE STRENGTH (Newton) BENDINGRADIUS(mm)
Temp. Perm.
B-6/SM/UT(2W)-PCCSTP-B12.0* UPTO 6 FIBRE 12.0 145±10 2000
80 120
B-8/SM/UT(2W)-PCCSTP-B12.0* 8 TO 12 FIBRE 12.0 145±10 2000
80 120
B-14/SM/UT(2W)-PCCSTP-B12.0* 14 TO 24 FIBRE 12.0 145±10 2000
80 120

MULTITUBE DESIGN

Multi Tube Design
Multi Tube Design
PHYSICAL PARAMETERS
PART NUMBER FIBRE COUNT DIAMETER(mm)(±1.0) WEIGHT(Kg./Km) TENSILE STRENGTH (Newton) BENDINGRADIUS(mm)
Temp. Perm.
B-12/SM/MT(F)-PCCSTP-B15.0* UPTO 12 FIBRE 15.0 200±15 2200
105 150
B-14/SM/MT(F)-PCSSTP-B15.0* 14 TO 24 FIBRE 15.0 200±15 2200
105 150
B-26/SM/MT(F)-PCCSTP-B15.0* 26 TO 48 FIBRE 15.0 210±15 2900
105 150
B-50/SM/MT(F)-PCSSTP-B16.0* 50 TO 96 FIBRE 16.0 250±20 4000
110 160

* In respect of lowest count fibre.
Cable can be provided with higher Tensile Strength
** Jacket material can be provided in LSZH compound on specific request.

STANDARDS : Bell core, EIA/TIA,ISO/IEC